The ability to configure combination starters for compact, reliable motor protection by combining a manual motor starter and a magnetic contactor.
- The combination starter protects the motor from short-circuitand overcurrent accidents in the three-phase motor circuit within a range between 15kW at 240V AC and 22kW at 415VAC, up to a current level of 50A.
- The manual motor starter provides overload, phase-loss, and short-circuit protections for the motor circuit, and incorporates a dial for flexible adjustment to match the total load current of the motor.
- The magnetic contactor allows remote ON/OFF operation of the motor circuit with high frequency, and features a electrical durability of one million operations.
- The manual motor starter and magnetic contactor are connected via link module and mounted to a base plate.
Feature
Design features
- Eight types available in two different frame sizes-32AF for the 45mm width and 63AF for the 55mm width
- A wide motor capacity range up to 30kW (400/415V AC, 63A)
- High breaking capacity Standard breaking capacity: 25, 50, 100kA 400V AC
High breaking capacity: 50, 100kA 400V AC - Adjustable thermal-magnetic trip types
32AF: BM3RSB and BM3RHB
63AF: BM3VSB and BM3VHB - Instantaneous trip types
32AF: BM3RSBK and BM3RHBK
63AF: BM3VSBK and BM3VHBK - Common accessories to reduce inventory
- Short-circuit protective coordination
IEC 60947-4-1 Type1, 2 - Standards IEC 60947-1, 60947-2, 60947-4-1, UL 508,CSA C22.2 No.14
- Ecological design
Recyclable thermoplastic resin used in plastic parts
Indication of materials used
Cadmium-free contacts - Both rocker and rotary handle
- ON/OFF and trip state indication for all frames
Types and ratings
Types and ratings (Connecting module)
Applicable MMS |
Applicable Magnetic Contactor | Magnetic Contactor Coil | Type | Mass[g] |
---|---|---|---|---|
BM3RSB BM3RHB |
SK06A, 09A, 12A | AC | BZ0LRK12AA | 25 |
SK06G, 09G, 12G,SK06L, 09L, 12L | DC | |||
SC-E02, E03, E04, E05 | AC | BZ0LRE22AA | 25 | |
SC-E02/G, E03/G, E04/G, E05/G | DC | BZ0LRE22GA | 35 | |
SC-E1 | AC | BZ0LRE32AA | 45 | |
SC-E1/G | DC | BZ0LRE32GA | 60 | |
BM3RSR BM3RHR |
SK06A, 09A, 12A | AC | BZ0LRK12AA | 25 |
SK06G, 09G, 12G,SK06L, 09L, 12L | DC | |||
SC-E02P,E03P,E04P,E05P | AC | BZ0LRE22AA | 25 | |
SC-E02P/G,E03P/G,E04P/G,E05P/G | DC | BZ0LRE22GA | 35 | |
SC-E1P | AC | BZ0LRP32AA | 45 | |
SC-E1P/G | DC | BZ0LRP32GA | 60 | |
BM3V | SC-E1, E2, E2S | AC | BZ0LVE51AA | 45 |
SC-E1/G, E2/G, E2S/G | DC | BZ0LVE51GA | 60 | |
SC-E3 | AC | BZ0LVE65AA | 65 | |
SC-E3/G | DC | BZ0LVE65GA | 80 |
Types and ratings (Base plate)
Applicable MMS |
Applicable Magnetic Contactor | Magnetic Contactor Coil | Type | Mass [g] |
---|---|---|---|---|
BM3RSB BM3RHB |
SK06A, 09A, 12A | AC | (BZ0BPRE22A) | 100 |
SK06G, 09G, 12G,SK06L, 09L, 12L | DC | |||
SC-E02, E03, E04, E05 | AC | BZ0BPRE22A | 100 | |
SC-E02/G, E03/G, E04/G, E05/G | DC | |||
SC-E1 | AC | BZ0BPRE32A | 160 | |
SC-E1/G | DC | |||
BM3RSR BM3RHR |
SK06A, 09A, 12A | AC | (BZ0BPRE22A) | 100 |
SK06G, 09G, 12G,SK06L, 09L, 12L | DC | |||
SC-E02P,E03P,E04P,E05P | AC | (BZ0BPRE22A)※2 | 100 | |
SC-E02P/G,E03P/G,E04P/G,E05P/G | DC | |||
SC-E1P | AC | BZ0BPRE32A | 160 | |
SC-E1P/G | DC | |||
BM3V | SC-E1, E2, E2S | AC | BZ0BPVE51A | 160 |
SC-E1/G, E2/G, E2S/G | DC | |||
SC-E3 | AC | BZ0BPVE65A | 195 | |
SC-E3/G | DC |