SENSORS

  • AC2 Interchangeable MgO insert – Industrial processes and furnaces

    Description

    • Amplified output signal
    • Temperature limits:
      -40 … + 350°C for type T
      -40 … + 550°C for type J
      -40 … + 600°C for type E
      -40 … +1050°C for type K
      (see table for sheath diameters)
    • Tolerance:
      UNI 7938, IEC standards 584.2 Class 1:
      for type T: ± 0,5° C (- 40 … + 125° C)
      ± 0.004 [t] (t > + 375° C)
      for type J, E, K: ± 1.5° C (- 40 … + 375° C)
      ± 0.004 [t] (t > + 375° C)
    • Mineral insulated interchangeable insert
    • Application versatility
  • AC6 Amplified output – General purpose

    Description

    • Temperature limits:
      -40 … +350°C for type T
      -40 … +750°C for type J
      -40 … +900°C for type E
      -40 … +1000°C for type K
      (see table for sheath diameters)
    • Tolerance (IEC standard 584.2/Class 2):
      for T:
      ± 1°C (-40 … +133°C)
      ± 0.0075 [t] (t > +133°C)
      for J, E, K:
      ± 2,5°C (-40 … +333°C)
      ± 0.0075 [t] (t > +333°C)
    • Ceramic insulation of the thermocouple element
    • Application versatility
  • AC6M MgO amplified output – General purpose

    Description

    • Amplified output signal o Temperature limits:
      -40 … +350°C for type T
      -40 … +750°C for type J
      -40 … +900°C for type E
      -40 … +1000°C for type K (see table for sheath diameters)
    • Tolerance:
      IEC 584.2 STANDARD class 1:
      or type T:
      ± 0,5° C (- 40 … + 125° C)
      ± 0.004 [t] (t > + 125° C)
      or type J, E, K:
      ± 1.5° C (- 40 … + 375° C)
      ± 0.004 [t] (t > + 375° C)
    • Mineral insulated (MgO) thermocouple element and continuous metal sheath
    • Application versatility
  • AC8 Amplified output – Steel industry

    Description

    • Amplified output signal
    • Temperature limits:
      – 40 … + 750° C per tipo J
      – 40 … + 900° C per tipo E
      – 40 … + 1000° C per tipo K
      (see table for sheath diameters)
    • Tolerance (IEC standard 584.2/Class 2):
      ± 2.5° C (- 40 … + 333° C)
      ± 0.0075 [t] (t > + 333° C)
    • Ceramic insulation of the thermocouple element
    • Application versatility
  • AC9 Amplified output and ceramic sheath – Steel industry

    Description

    • Amplified output signal
    • Temperature limits:
      -40 … +1200°C for type K
      0 … +1400°C for types S and R
      +600 … +1600°C for type B
      (see table for sheath diameters)
    • Tolerance (IEC standard 584.2/Class 1):
      for type K:
      ± 2.5° C (- 40 … + 333° C)
      ± 0.0075 x [t] (t > + 333° C)
      for type S, R,
      ± 1° C 0…+1100
      ± [1+0,003 x (t -1100)]°C +1100…+1600°C
      for type B:
      +600° C … + 1700°C
      ± 0.0025 x [t]
    • Ceramic insulation of the thermocouple element
    • Application versatility
  • Accessories for resistance thermometers Cables, protective sheathings, fittings, heads, amplifiers, adapter, display, remote inputs, connectors

    Overview

    • Extension and compensation cables for Thermocouples
    • Protective sheathings
    • Sliding compression fittings
    • Connection heads
    • 4-20ma signal amplifiers
    • Adapter for 4-20ma signal amplifiers
    • Display
    • IP67 remote temperature inputs on CANpen fieldbus
    • Connectors
  • Accessories for termocouples Cables, protective sheathings, fittings, heads, amplifiers, adapter , display, remote inputs, connectors

    Overview

    Accessories: cables, protective sheathings, fittings, heads, amplifiers, adapter , display, remote inputs, connectors

  • AM Miniature force transducer

    Overview

    The AM force transducers series have been designed to measure static and dynamic compression forces.
    They are particularly suitable for monitoring pounding operations in compression which require a rugged transducer, insensitive to high resonance frequencies caused by non-homogeneous leads in dynamic sequences.
    The accuracy and the stability are not affected by continuous cycling under harsh conditions even with dynamic loads.
    The small size of the AM force transducers makes them ideal for retrofitting in existing equipment.

  • AN1068 Strain ring

    Overview

    • Fast and easy strain measurement on cylinders (magnetic or not)
    • Clamp the strain ring around the tie bar and measure
    • 0,5% accuracy
    • Without calibration
    • Ideal for cyclical applications, e.g. clamping force measurements on presses

  • AR2 Amplified output with interchangeable MgO insert

    Description

    • Amplified output signal
    • Temperature limits:
      -200 … +600°C
    • Tolerance: UNI 7937, IEC 751 standards:
      ± 0.15°C at 0°C for class A (1/2 DIN)
      ± 0.30°C at 0°C for class B (1 DIN)
      ± 0.10°C at 0°C for 1/3 DIN class
    • Insulation: > 100 MOhm for voltage values from 10 to 100 Vcc o
    • PT100 wire-wound resistance thermometer
    • Mineral insulated interchangeable insert
    • Application versatility
  • AR6 Amplified output – General purpose

    Description

    • Transmitter 4…20mA
    • Amplified output signal
    • Temperature limits: – 40 … + 300° C
    • Tolerance: UNI 7937, IEC 751 standards:
      ± 0.15° C a 0° C for class A (1/2 DIN)
      ± 0.30° C a 0° C for class B (1 DIN)
      ± 0.10° C a 0° C for 1/3 DIN class
    • Ceramic insulation of sensor, PT100 at 0° C
    • Application versatility
  • AR6M MgO amplified output – General purpose

    Description

    • 4…20mA Transmitter
    • Amplified output signal
    • Temperature limits: – 200 … + 600° C
    • Tolerance: UNI 7937, IEC 751 standards:
      ± 0.15° C a 0° C for class A (1/2 DIN)
      ± 0.30° C a 0° C for class B (1 DIN)
      ± 0.10° C a 0° C for 1/3 DIN class
    • Compact mineral insulated (MgO) resistance thermometer element (Pt100 at 0°C) and continuous metal sheath
    • Application versatility
RSS