Inverters for elevators

  • ADL300 Lift Field oriented vector inverter for synchronous/asynchronous motors

    0 out of 5

    Overview

    Power Data

    Power Supply:

    • Version ADL300-4: 3ph 230 – 400 – 480Vac (-15% / +10%) @ 50/60Hz (±5%).
    • Version ADL300-2T: 3ph 200 – 230Vac (±10%) @ 50/60Hz (±2%)
    • Version ADL300-2M: 200Vac (-10%) ….230Vac (+15%) @ 50/60Hz (±2%)

    Motor Ratings:

    • Version ADL300-4: 4kW (5Hp) …. 75kW (100Hp).
    • Version ADL300-2T: 4kW (5Hp) …. 37kW (40Hp).
    • Version ADL300-2M: 1.1kW (1Hp) …. 5.5kW (7.5Hp).

    EMC & Mark Compliances:

    • Integrated EMI Filter for EN 12015; EN 61800-3 2nd environment, category C2 and C3
    • CE Mark
    • UL and cUL Elevator Accessory E365347 certified also evaluated in accordance with ASME A17.5 and CSA B44.1.
    • Compliant to UNI EN 81-1:1998 + A3:2009, article 9.11.3
    • Safety Torque Off (STO) EN61800-5-2-2007 SIL3 Certified

    Main Features

    • Control in Speed
    • Control in Position
    • Direct Approach
    • Relevelling
    • Short Floor Management
    • Emergency single-phase power supply for floor return
    • DCP3 and DCP4 Protocol
    • CANopen CiA™ 301 Protocol
    • CANopen Lift CiA™ 417 Protocol
    • Integrated Breaking Unit
    • External +24Vdc power supply for low stand-by consumption
    • Peripheral Encoder Management

    Product Set-Up
    The configuration set-up can be done by the following:

    • 7 segments digit Keypad (integrated)
    • Optional alphanumeric keypad (KB-ADL)
    • PC with Graphical User Interface GF-eXpress

    Easy and safe start-up
    Thanks to the Wizard and the different access profiles (easy and expert) the configuration of the drive is fast and intuitive. The still autotuning is quickly performed, avoiding operators to decouple the car from the ropes, assuring a safe working environment and a faster commissioning.

    Available Configurations
    3 different configurations to answer all the requirements:

    BASIC

    • 8 programmable digital inputs (NPN/PNP) + 1 Enable input
    • 4 single-contact programmable relay outputs
    • 5 Vdc TTL incremental digital encoder
    • Absolute SinCos encoder

    BASIC ENDAT

    • 8 programmable digital inputs (NPN/PNP) + 1 Enable input
    • 4 single-contact programmable relay outputs
    • Absolute Endat 2.1/2.2 and SSI

    ADVANCED

    • Extended Pluggable optional I/O cards
    • Extended Pluggable Optional Encoder cards
    • 24Vdc HTL incremental digital encoder

    Options

    • KB-ADL multilingual programming keypad with memory (up to 5 configurations)
    • Dedicated external EMC filters (for version without integrated EMC Filter).
    • External braking resistors
    • AC and DC input chokes
  • AGL50 – EV Lift Space Vector inverter

    0 out of 5

    Overview

    Power Data
    * Power supply: 3 x 400 – 480Vac (-15% / +10%) @ 50Hz (-2%) / 60Hz (+2%)
    * Motor power ratings: 4kW (5Hp) – 5.5kW (7.5Hp) – 7.5kW (10Hp)
    * Overload: 170% for 10 seconds
    * Motor type: Asynchronous

    EMC & Mark Compliances:

    • CE Mark

    Main Features

    • Compact Dimensions
    • Multispeed control
    • Short floor management
    • Flexible ramps management
    • Self-tuning of motor parameters
    • Lift sequences
    • Integrated Motor control
    • Integrated brake control
    • Integrated braking unit

    Product Set-Up
    The configuration set-up can be done by the following:

    • Integrated keypad
    • PC with Graphical User Interface GF-eXpress

    Easy and safe start-up
    Thanks to the User-friendly menu the configuration of the drive is fast and intuitive.

    Options:

    • External EMC filters (in compliance with EN12015)
    • Input and Output chokes
    • Braking resistors
  • AVRy Lift Field-Oriented vector inverter for synchronous motors with built-in power recovery

    0 out of 5

    Overview

    Power Data
    * Power supply: 3 x 400Vac….480Vac 50/60Hz
    * Motor power ratings from 11kW (7.5Hp) to 27kW (20Hp), @ 400Vac
    * Overload: 183% for 10 seconds
    * Motor type: Synchronous

    EMC & Mark Compliances:
    CE Mark

    Main Features

    • Integrated Regenerative Unit
    • Unitary power factor (cosphi)
    • Low harmonic distortion of input current <4%
    • Multispeed control
    • Short floor management
    • Flexible ramp management
    • Management of TTL incremental digital encoder
    • Management of SinCos absolute encoder
    • “Space vector” modulation reduces noise levels to a minimum.
    • Motor parameters self tuning

    Product Set-Up
    The configuration set-up can be done by the following:

    • Integrated programming keypad
    • PC with Graphical User Interface GF-eXpress

    Easy and safe start-up
    Thanks to the User-friendly menu the configuration of the drive is fast and intuitive.

  • VDL200 Lift-field-oriented vector inverter for asynchronous motors

    0 out of 5

    Overview

    Power Data
    * Power supply: 3 x 230-400Vac, -15%+10%, 50Hz
    * Motor power ratings from 4kW to 11kW
    * Overload: 200% for 10 seconds
    * Motor type: Asynchronous

    EMC & Mark Compliances:

    • Integrated EMI Filter for EN 12015; EN 61800-3 2nd environment, category C2 and C3
    • CE Mark
    • Conforms to UNI EN 81-1:1998 + A3:2009, article 9.11.3

    Main Features

    • Multispeed control
    • Short floor management
    • Emergency single-phase power supply for floor return with low energy optimization
    • Flexible ramp management
    • Integrated braking unit
    • Communication with control board via I/O
    • Management of TTL incremental digital encoders
    • Integrated EMI filter for versions (VDL200….-F)

    Product Set-Up

    • The configuration set-up can be done by the following:
    • Optional alphanumeric keypad (KB-ADL)
    • PC with Graphical User Interface GF-eXpress

    Easy and safe start-up
    Thanks to the Wizard and the different access profiles (easy and expert) the configuration of the drive is fast and intuitive. The still autotuning is quickly performed, avoiding operators to decouple the car from the ropes, assuring a safe working environment and a faster commissioning.

    Options

    • KB-ADL multilingual programming keypad with memory (up to 5 configurations)
    • Dedicated external EMC filters (for version without integrated EMC Filter).
    • External braking resistors
    • AC and DC input chokes