MOTION CONTROL

  • ADL300 Lift Field oriented vector inverter for synchronous/asynchronous motors

    0 out of 5

    Overview

    Power Data

    Power Supply:

    • Version ADL300-4: 3ph 230 – 400 – 480Vac (-15% / +10%) @ 50/60Hz (±5%).
    • Version ADL300-2T: 3ph 200 – 230Vac (±10%) @ 50/60Hz (±2%)
    • Version ADL300-2M: 200Vac (-10%) ….230Vac (+15%) @ 50/60Hz (±2%)

    Motor Ratings:

    • Version ADL300-4: 4kW (5Hp) …. 75kW (100Hp).
    • Version ADL300-2T: 4kW (5Hp) …. 37kW (40Hp).
    • Version ADL300-2M: 1.1kW (1Hp) …. 5.5kW (7.5Hp).

    EMC & Mark Compliances:

    • Integrated EMI Filter for EN 12015; EN 61800-3 2nd environment, category C2 and C3
    • CE Mark
    • UL and cUL Elevator Accessory E365347 certified also evaluated in accordance with ASME A17.5 and CSA B44.1.
    • Compliant to UNI EN 81-1:1998 + A3:2009, article 9.11.3
    • Safety Torque Off (STO) EN61800-5-2-2007 SIL3 Certified

    Main Features

    • Control in Speed
    • Control in Position
    • Direct Approach
    • Relevelling
    • Short Floor Management
    • Emergency single-phase power supply for floor return
    • DCP3 and DCP4 Protocol
    • CANopen CiA™ 301 Protocol
    • CANopen Lift CiA™ 417 Protocol
    • Integrated Breaking Unit
    • External +24Vdc power supply for low stand-by consumption
    • Peripheral Encoder Management

    Product Set-Up
    The configuration set-up can be done by the following:

    • 7 segments digit Keypad (integrated)
    • Optional alphanumeric keypad (KB-ADL)
    • PC with Graphical User Interface GF-eXpress

    Easy and safe start-up
    Thanks to the Wizard and the different access profiles (easy and expert) the configuration of the drive is fast and intuitive. The still autotuning is quickly performed, avoiding operators to decouple the car from the ropes, assuring a safe working environment and a faster commissioning.

    Available Configurations
    3 different configurations to answer all the requirements:

    BASIC

    • 8 programmable digital inputs (NPN/PNP) + 1 Enable input
    • 4 single-contact programmable relay outputs
    • 5 Vdc TTL incremental digital encoder
    • Absolute SinCos encoder

    BASIC ENDAT

    • 8 programmable digital inputs (NPN/PNP) + 1 Enable input
    • 4 single-contact programmable relay outputs
    • Absolute Endat 2.1/2.2 and SSI

    ADVANCED

    • Extended Pluggable optional I/O cards
    • Extended Pluggable Optional Encoder cards
    • 24Vdc HTL incremental digital encoder

    Options

    • KB-ADL multilingual programming keypad with memory (up to 5 configurations)
    • Dedicated external EMC filters (for version without integrated EMC Filter).
    • External braking resistors
    • AC and DC input chokes
  • ADP200 Inverter for servopump hybrid injection machines

    0 out of 5

    Overview

    Full vector Inverter from 7.5 kW up to 75 kW with special PID function for servopump hybrid injection machines

    * Mains supply:
    – 3 x 230-400 -480 VAC, 50/60Hz
    * Motor ratings from 7,5kW (10Hp) to 75kW (100Hp)

    * Certifications: CE

    Features:

    • Motor type: Synchronous Motors
    • Regulation control mode: Vector control with feedback (Encoder expansion card mandatory)
    • Max Output frequency 300Hz
    • DC side choke integrated in ADP200-4300…5750 models.
    • AC side external choke mandatory in ADP200-5S550 and ADP200-5S750 models
    • EMC Filter Integrated in -F models (EN61800-3 category C2 and C3)
    • Dynamic Braking Module Integrated with external resistor (except ADP200-5750 model)
    • Overload management 170% x In (per 60 sec.), 200% x In (per 3 sec)
    • Multilanguage programming software
    • Advanced programming via MDPLC tool (IEC 61131-3 standard environment)
    • Integrated simplified programming keypad and optional keypad with multiple languages LCD display
    • 3 differential analog inputs:
      1 for pressure sensor:
      Voltage: 0…10 V or 0.1…10.1 V (3 wires)
      Current: 0…20 mA or 4…20mA (2 wires)

    2 for flow/pressure references or general purpose:
    Voltage: +/- 10 V
    Current: 0…20 mA or 4…20 mA

    • 1 Analog output: 0…10 V o 0~20mA /4~20mA
    • 6 Digital Inputs + enable
    • 2 Digital Outputs
    • 2 Relay Outputs
    • 1 motor protection input (compatible with PTC, KTY, Klixon)
    • RS485 Serial Line (Modbus RTU protocol)
    • Integrated CAN fieldbus communication (in –C version)
    • Speed feedback through Resolver card
    • Wide range of optional encoder cards
    • Integrated Slot for SD card
    • IP20 protection degree

    *Above listed features represent standard configuration with EXP-IO-D8A4R2-ADP (I/O card) and EXP-RES-I1-ADP (resolver card)

  • ADV200 Field-Oriented vector inverter

    0 out of 5

    Overview

    Field-oriented vector inverter, from 0.75kW up to 1.65MW

    * Mains supply:
    – 3 x 380…500Vac, 50/60Hz (-4 models )
    – 3 x 690Vac, 50/60Hz (-6 models )
    – 450…750Vdc (-DC-4 models)
    – 600…1120Vdc (-DC-6 models)

    * Motor ratings from 0.75kW (1Hp) to 1.65MW (2200Hp)
    * Certifications: CE. UL, cUL

    Features:

    •     Regulation control modes: FOC with Speed feedback, FOC open loop, V/F
    •     Max Output frequency 500Hz
    •     DC Choke integrated up to 132kW
    •     EMC Filter integrated
    •     Dynamic Braking Module integrated up to 55kW
    •     Overload according with IEC146 Class 1 and Class 2
    •     Heavy duty and Light duty overload management
    •     Up to 4 options on board
    •     Safety Stop card in accordance with EN 954-1 (Cat.3)
    •     Multilanguage programming software (5 languages)
    •     Advanced PLC according to the IEC61131-3 Standard
    •     Basic PLC Integrated
    •     Alphanumeric programming keypad
    •     2 Bipolar Analogue Inputs  (Voltage/Current)
    •     2 Bipolar Analogue Outputs (1: Voltage/Current, 1: Voltage)
    •     6 Digital Inputs (PNP / NPN)
    •     2 Digital Outputs (PNP / NPN)
    •     2 Relay Outputs, single contact
    •     RS485 Serial Line (Modbus RTU protocol)
    •     Interfacing with the more common field bus: ProfiBus, CANopen, DeviceNet, EtherNet real.time GDNet, EtherCAT, EtherNet/IP, Profinet
    •     IP20 protection degree as standard
  • ADV200 HC Field-Oriented vector inverter for Hoist & Crane applications

    0 out of 5

    Overview

    Field-oriented vector inverter, from 0.75kW up to 1.65MW
    * Mains supply:
    – 3 x 380…500Vac, 50/60Hz (-4 models )
    – 3 x 690Vac, 50/60Hz (-6 models )
    – 450…750Vdc (-DC-4 models)
    – 600…1120Vdc (-DC-6 models)

    * Motor ratings from 0.75kW (1Hp) to 1.65MW (2200Hp)
    * Certifications: CE. UL, cUL

    Functions:

    • Self-tuning rotational and stand still of speed-current-flux regulators and motor data identification
    • Torque control
    • Simplified Start-up menu
    • Instantaneous Overload up to 180%
    • Motor, Drive and Braking resistor I2t thermal protection
    • 100% torque at zero-speed
    • Braking management
    • Function hoist speed-up
    • Function Anti-Sway
    • Function Overtravel,
    • Function Anti impact
    • Function Master/Follower
    • Multispeed function (16 programmable preset)
    • 4 independent programmable Multi-ramp
    • Double motor parameters setting
    • Joystick management
    • CT an VT operating mode
    • Memory Keypad with 5 parameters set

    Options:

    • I/O expansion cards, configurable according to the customer’s machine needs
    • Expansion cards for the management of auxiliary encoders
    • Field-bus interface cards: ProfiBus , CANopen, DeviceNet, GDNet, EtherCAT, EtherNet/IP
    • Safety Stop card in accordance with EN 954-1 (Cat.3) PL “e”
    • Braking resistors (standardized for the whole line)
    • Dedicated EMC filters (in compliance with CEE – EN61800-3:2004)
    • Input & Output chokes (standardized for the whole line)
    • OPT-485-ADV, RS485 optoisolatore per collegamenti multidrop in RS485
    • BUy, External Braking Unit for drives power over 55kW
    • AFE200 Regen Active Front End power supply unit
    • KB-ADV Remotable keypad kit

    Features:

    • Regulation control modes: FOC with Speed feedback, FOC open loop, V/F
    • Max Output frequency 500Hz
    • DC Choke integrated up to 132kW
    • EMC Filter integrated
    • Dynamic Braking Module integrated up to 55kW
    • Heavy duty and Light duty overload management
    • Up to 4 options on board
    • Multilanguage programming software (5 languages)
    • Alphanumeric programming keypad
    • 2 Bipolar Analogue Inputs  (Voltage/Current)
    • 2 Bipolar Analogue Outputs (1: Voltage/Current, 1: Voltage)
    • 6 Digital Inputs (PNP / NPN)
    • 2 Digital Outputs (PNP / NPN)
    • 2 Relay Outputs, single contact
    • RS485 Serial Line (Modbus RTU protocol)
    • Interfacing with the more common field bus: ProfiBus, CANopen, DeviceNet, EtherNet real.time GDNet, EtherCAT, EtherNet/IP, ProfiNet
    • IP20 protection degree as standard (IP00 size 7 and parallel unit)
  • ADV200 LC Liquid cooled field-oriented vector inverter

    0 out of 5

    Overview

    Field-oriented vector inverter, from 30kW up to 400kW
    * Mains supply: 3 x 380…500Vca, 50/60Hz
    * Motor ratings from 30kW (40Hp) to  400kW (500Hp)
    * Certifications: CE, UL, cUL

    Features:

    • Regulation control modes: FOC with Speed feedback, FOC open loop, V/F
    • Max Output frequency 500Hz
    • DC Choke integrated up to 200kW
    • EMC Filter integrated
    • Dynamic Braking Module integrated (up to 90kW)
    • Optional integrated braking resistor  (up to 55kW)
    • Overload according with IEC146 Class 1 and Class 2
    • Heavy duty and Light duty overload management
    • Up to 3 options on board
    • Safety Stop card in accordance with EN 954-1 (Cat.3) PL “e”
    • Multilanguage programming software (5 languages)
    • Advanced PLC according to the IEC61131-3 Standard
    • Alphanumeric programming keypad
    • 2 Bipolar Analogue Inputs (Voltage/Current/PTC-KTY input)
    • 2 Bipolar Analogue Outputs (1: Voltage/Current, 1: Voltage)
    • 6 Digital Inputs (PNP / NPN)
    • 2 Digital Outputs (PNP / NPN)
    • 2 Relay Outputs, single contact
    • RS485 Serial Line (Modbus RTU protocol)
    • Interfacing with the more common field bus: ProfiBus, CANopen, DeviceNet, EtherNet real.time GDNet, EtherCAT, EtherNet/IP,  ProfiNet
    • IP00 protection degree as standard
  • ADV200 System Field-oriented vector inverter & regen suppliers in cabinet solutions

    0 out of 5

    Overview

    Inverter panels from 90 kW to 1.2 MW

    3-phase power supply:

    • 400 V – 15% …. 480 V +10%
    • 500 V – 10% …. 690 V +10%
    • 50 Hz – 2% …. 60 Hz +2%

    Line entry: bottom
    Motor cable exit: bottom
    Terminal board: bottom
    Access: front
    Colour: RAL 703
    Protection rating: IP31 – IP54
    Installation: 1,000 m a.s.l. (up to 2,000 m with derating)
    Ambient temperature:

    • IP31 – 40°C (unless otherwise specified in the catalogue)
    • IP54 – 35°C (unless otherwise specified in the catalogue)

    Approval and technical standards

    • CE: compliant with the EEC low voltage equipment directive
    • EMC: compliant with EEC directive – EN 61800-3
    • Panels built in accordance with IEC EN 50178 and IEC EN 60204-1

    Versions

    Panels are available with power ratings from 90 kW to 1.2 MW with standard input bridge or the “Active Front End” solution, in two main versions.

    • Ready to use
    • Basic

    The “Ready to use” version is supplied as a complete panel ready to be installed. It includes the entire power section, from the automatic line circuit breaker to the motor connection bars, all the auxiliary circuits and controls needed to start a single-motor system, all of which are supplied as standard.

    In the “Basic” version, the entire power section, from the automatic line circuit breaker to the output bars for connecting the motor, is supplied with the panel as standard. The appropriate auxiliary circuits can be added by the customer as required.

    • Sizing for low overload currents (Light Duty)
    • Sizing for high overload currents (High Duty)

    Light Duty panels are designed to guarantee the rated current of the motor and an overload of 110% for 60 seconds every 300 seconds.
    High Duty panels are designed to guarantee the rated current of the motor and an overload of 150% for 60 seconds every 300 seconds.

    Standard equipment

    Ready to use version

    • Automatic line circuit breaker with minimum voltage coil
    • Emergency circuit with safety relay
    • ADV200 inverters with integrated EMC filters (compliant with EEC Directive – EN61800-3)
    • Line choke (integrated as standard in ADV200 inverters up to size 132 kW, external for bigger sizes)
    • Fast-acting fuses to protect inverter modules for sizes from 400 kW in the High Duty version and 500 kW in the Light Duty version
    • Inverter fan unit power supply from size 160 kW in the High Duty version and 200 kW in the Light Duty version with overload switch
    • Motor fan unit power supply with overload switch
    • Auxiliary circuits with relative protection
    • Flashing “doors open” indicators
    • Controls on door:
      Machine ON button
      Power indicator lamp
      Reset alarm button
      “Local” or “Remote” switch
      “Local” motor operation button
      Motor running indicator lamp
      Stop motor button
      Alarm indicator lamp
      Emergency mushroom pushbutton
    • Inverter programming keypad on panel door

    Basic version

    • Automatic line circuit breaker with minimum voltage coil
    • ADV200 inverters with integrated EMC filters (compliant with EEC Directive – EN61800-3)
    • Line choke (integrated as standard in ADV200 inverters up to size 132 kW, external for bigger sizes)
    • Fast-acting fuses to protect inverter modules for sizes from 400 kW in the High Duty version and 500 kW in the Light Duty version
    • Inverter fan unit power supply from size 160 kW in the High Duty version and 200 kW in the Light Duty version with overload switch.
    • Motor fan unit power supply with overload switch

    Accessories (optional)

    Gefran offers a range of accessories to meet the various requirements of the machines where the panels are installed.

    • EXP-SFTy-ADV safety card: designed to implement the STO (Safety Torque Off) function to prevent unexpected motor start-up.
      The card meets the requirements of the following new directives: Safety Integrity Level SIL 3 according to EN 61508 and EN 61800-5-2.
      The safety card can be used to implement a Category 0 emergency stop function when the drive is connected to the power supply, according to EN 60204-1.
      When ordering the safety card, please specify the required SIL so that the external circuitry can be engineered accordingly (for the Ready to use version only).
    • BUS interface: GDnet, CANopen, Devicenet, Profibus, Ethercat (Modbus RTU integrated as standard)
    • Expansion of digital and analog inputs/outputs
    • Encoder input/repetition card. Interfaces are available for TTL/HTL digital incremental encoders, Sinusoidal encoders, ENDAT/SSI/HIPERFACE absolute encoders.
    • Output chokes
    • Power contactor
    • PT100 relay
    • BUy dynamic braking module and braking resistors
    • Service plug with 10 A fuse
    • Service lamps inside panel
    • Passive harmonic filters
    • Dedicated EMC filter
    • Customised doors
    • One door free for use by customer
    • Anti-condensation elements
    • Cable entry/exit at top
  • ADV200 WA Field-Oriented vector inverter for water treatment and HVAC

    0 out of 5

    Overview

    Field-oriented vector inverter, from 1,5kW up to 1.8MW
    * Mains supply:
    – 3 x 380…500Vac, 50/60Hz (-4 models )
    – 3 x 690Vac, 50/60Hz (-6 models )
    – 450…750Vdc (-DC-4 models)
    – 600…1120Vdc (-DC-6 models)
    * Motor ratings from 1,5kW (2Hp) to 1.8MW (2400Hp)
    * Certifications: CE. UL, cUL

    Features:

    • Regulation control modes: Open Loop FOC, V/F
    • Max Output frequency 500Hz
    • DC Choke integrated up to 160kW
    • EMC Filter integrated
    • Dynamic Braking Module integrated up to 75kW
    • Overload according with IEC146 Class 1 and Class 2
    • Light duty and heavy duty overload management
    • Up to 4 options on board
    • Safety Stop card in accordance with EN 954-1 (Cat.3)
    • Multilanguage programming software (5 languages)
    • Advanced PLC according to the IEC61131-3 Standard
    • Basic PLC Integrated
    • Alphanumeric programming keypad
    • 2 Bipolar Analogue Inputs  (Voltage/Current)
    • 2 Bipolar Analogue Outputs (1: Voltage/Current, 1: Voltage)
    • 6 Digital Inputs (PNP / NPN)
    • 2 Digital Outputs (PNP / NPN)
    • 2 Relay Outputs, single contact
    • RS485 Serial Line (Modbus RTU protocol)
    • Interfacing with the more common field bus: ProfiBus, CANopen, DeviceNet, EtherCAT, EtherNet/IP, BACnet, LonWorks
    • IP20 protection degree as standard
    • IP54 external with enclosure (7,5 – 90 kW)
  • AFE200 Regenerative active front end power suppliers

    0 out of 5

    Overview

    The AFE200 offers a number of advantages:

    •  “Clean Power” thanks to the unit power factor and reduced harmonic distortion (<5%)
    • Enhanced system dynamics during drive and regeneration
    • Considerable energy savings during regeneration transients
    • Improved stability of the DC Bus circuit under load changes
    • Significant cost-effectiveness with the single power supply system
    • Elimination of uneconomical conventional braking systems and braking resistors

    The AFE200 range has power ratings of 22kW to 1.65MW for three-phase power supplies of 400VAC to 690VAC.
    Ease of use and intuitive programming make it possible for users of any level to exploit the high-level performance of Active Front End technology for a broad range of applications where there is a need for real energy saving.

    Options

    • LCL filter (mandatory)
    • Pre-load kit, includes resistor and 2 pre-load contactors (mandatory)
    • External EMI mains filter
  • AGL50 – EV Lift Space Vector inverter

    0 out of 5

    Overview

    Power Data
    * Power supply: 3 x 400 – 480Vac (-15% / +10%) @ 50Hz (-2%) / 60Hz (+2%)
    * Motor power ratings: 4kW (5Hp) – 5.5kW (7.5Hp) – 7.5kW (10Hp)
    * Overload: 170% for 10 seconds
    * Motor type: Asynchronous

    EMC & Mark Compliances:

    • CE Mark

    Main Features

    • Compact Dimensions
    • Multispeed control
    • Short floor management
    • Flexible ramps management
    • Self-tuning of motor parameters
    • Lift sequences
    • Integrated Motor control
    • Integrated brake control
    • Integrated braking unit

    Product Set-Up
    The configuration set-up can be done by the following:

    • Integrated keypad
    • PC with Graphical User Interface GF-eXpress

    Easy and safe start-up
    Thanks to the User-friendly menu the configuration of the drive is fast and intuitive.

    Options:

    • External EMC filters (in compliance with EN12015)
    • Input and Output chokes
    • Braking resistors
  • AVRy Lift Field-Oriented vector inverter for synchronous motors with built-in power recovery

    0 out of 5

    Overview

    Power Data
    * Power supply: 3 x 400Vac….480Vac 50/60Hz
    * Motor power ratings from 11kW (7.5Hp) to 27kW (20Hp), @ 400Vac
    * Overload: 183% for 10 seconds
    * Motor type: Synchronous

    EMC & Mark Compliances:
    CE Mark

    Main Features

    • Integrated Regenerative Unit
    • Unitary power factor (cosphi)
    • Low harmonic distortion of input current <4%
    • Multispeed control
    • Short floor management
    • Flexible ramp management
    • Management of TTL incremental digital encoder
    • Management of SinCos absolute encoder
    • “Space vector” modulation reduces noise levels to a minimum.
    • Motor parameters self tuning

    Product Set-Up
    The configuration set-up can be done by the following:

    • Integrated programming keypad
    • PC with Graphical User Interface GF-eXpress

    Easy and safe start-up
    Thanks to the User-friendly menu the configuration of the drive is fast and intuitive.

  • AXV300 Modular servodrives

    0 out of 5

    Overview

    * 3 x 400 VAC, 50/60 Hz
    * Motor ratings from 2.7 kW (3.6 Hp) to 120 kW (160 Hp)
    * IP20 protection rating
    * Markings: CE

    General characteristics:
    all AXV300 modules need a 24 VDC supply voltage to power the regulation card/internal logic and fans.

    AXV300 range of Axis Modules:
    motor control loop (brushless or asynchronous);
    current loop closing: 16 KHz (62.5 μsec);
    speed loop closing: 4 KHz (250 μsec);
    I2t overload: slow (150% In x 60 sec) and fast (200% In x 0.5 sec);
    management of local encoder for closing current/speed loops;
    alarm management;
    management of GStar communication from/to the AXV300-CU control module;

    AXV300-SM power supply module:
    DC-link output voltage: 565 VDC
    output power 11-22-44 Kw
    thermal overload and pre-alarm output for external PLC
    integrated braking unit
    indicator LEDs
    external pre-charge contactor output
    I2t overload

    AXV300-SR + AXV300-AFE-SR Regenerative supply module:

    AXV300-AFE-SR: regenerative supply control module
    indicator LEDs
    signal display
    external pre-charge contactor output

    AXV300-SR: range of power modules for regenerative supply modules
    DC-link output voltage: 625 VDC
    used with the AXV300 AFE-SR control module it forms the system’s regenerative supply module
    I2t overload: slow (150% In x 60 sec) and fast (200% In x 0.5 sec);

    AXV300-CU: Control Unit module:
    System initialisation
    System alarm management
    Software updates
    2-way GSTAR optical fibre system for communication with axes (max 4×2 axes)
    Set-point calculation/transmission
    Reading of significant values
    MDPlc development environment
    Execution of application (e.g. Positioner, Electric Shaft ..)
    Fieldbus communication (CANopen port)
    Modbus RTU RS232 connection
    Programmed via PC using the GF_eXpress configurator
    Serial port for connection to auxiliary programming keypad (currently being developed)
    SD-card for storing configurations and downloading system data
    Standard I/O
    •    2 analog inputs -10 V…+10 V
    •    1 analog output -10 V…+10 V @ 5 mA
    •    4 opto-isolated digital inputs HTL 0…30 V
    •    2 opto-isolated digital outputs 30 V @ 40 mA
    •    1 opto-isolated digital output 30 V @ 500 mA
    Encoder management (with additional module)
    • Digital encoder
    • Sinusoidal encoder
    • 5-track SinCos encoder
    • 2-pole resolver
    • Encoder with EN-DAT 2.1/EN-DAT 2.2 protocol
    • Absolute encoder with SSI/BiSS protocol
    Control unit communication via high-speed fieldbus (with additional GD-Net, Ethercat, etc. module);

  • BDI50 Compact v/f & sensorless inverter

    0 out of 5

    Overview

    BDI50 – Compact V/f and sensorless inverter, from 0.4kW up to 11 kW

    * Mains supply:

    – 1 x 200…240Vac, 50/60Hz (-2M models)

    – 3 x 200…240Vac, 50/60Hz (-2T models)

    – 3 x 380…480Vac, 50/60Hz (-4 models)

    * Motor ratings from 0.4kW (0.5Hp) to 11kW (15Hp)

    * Certifications: CE, cULus

    Features:

    •     Motor type: Asynchronous Motor
    •    Regulation control modes: V/f, Sensorless (SLV)
    •     Max Output frequency 599Hz
    •     EMC Filter integrated (models -2M and -4)
    •     RFI-switch for IT mains
    •     Dynamic Braking Module integrated on models -4
    •     Overload 150%/1min
    •     8 preset speeds
    •     Multilanguage programming software
    •     Integrated programming keypad
    •     2 Analog inputs: AVI: 0~10V/2~10V, ACI: 0~20mA / 4~20mA
    •     1 Analog output: 0-10V
    •     5 Digital Inputs (PNP / NPN depending on models)
    •     Digital Outputs: 1, relay
    •     Motor protection input: by PTC (AVI)
    •     RS485 Serial Line (Modbus RTU/ASCII protocol)
    •    Integrated Bacnet protocol
    •     Interfacing with the most common fieldbus through communication modules for ProfiBus, CANopen, DeviceNet, TCP-IP
    •      IP20 protection degree